Washington State Masonry Code Amendments
1405.5.2 Seismic requirements. Anchored
masonry veneer located in Seismic Design Category C, D, E, or F
shall conform to the requirements of Section 6.2.2.10, except
Section 6.2.2.10.3.2, of the ACI 530/ASCE 5/TMS 402.
2106.1.1
Seismic design.
Exception: Special reinforced masonry shear walls are not
required to comply with Section 1.14.2.2.5(a) of ACI 530/ASCE
5/TMS 402 (MSJC-05), provided the masonry resists the calculated
shear without shear reinforcement.
2108.2
Headed and bent-bar anchor bolts.
ACI 530/ASCE 5/TMS 402, Section 3.1.6.
Modify Section 3.1.6 as follows:
3.1.6 Headed and bent-bar
anchor bolts. All embedded bolts shall be grouted in place,
except that 1/4 inch (6.4 mm) diameter bolts are permitted
to be placed in bed joints that are at least 1/2 inch (12.7
mm) in thickness.
(Existing Section 2108.2 and
remaining sections are renumbered)
Oregon State Masonry Code Amendments
1402.1
Anchored masonry veneer. Veneer
secured with approved mechanical fasteners to an approved
backing. Type and spacing of fasteners shall be noted on
construction documents.
1405.5.2
Seismic requirements. Anchored masonry
veneer located in Seismic Design Category C, D, E, or F shall
conform to the requirements of Section 6.2.2.10, except Section
6.2.2.10.3.2, of ACI 530/ASCE 5/TMS 402. Mechanically attached
anchors to the joint reinforcement, as required in ACI 530/ASCE
5/TMS 402 Section 6.2.2.10.3.3 with clips and hooks, shall be
required in Seismic Design Category D, Section 6.2.2.10.2, for
occupancy category III and IV.
2104.6
Embedded bolts. All embedded bolts
shall be grouted in place.
Exception: Bolts not exceeding 1/4 inch (6.4 mm) diameter
are permitted to be placed in bed joints that are at least 1/2
inch (12.7 mm) in thickness.
2104.7
Cleanouts. A minimum clean-out of size
1-1/8" high x 4-1/4" long be provided at the bottom course at each vertical bar for all grout pours over 5
feet (1524 mm) in height. Where cleanouts are not provided,
special provisions must be made to keep the bottom and sides of
the grout spaces clean and clear prior to grouting.
2106.1.1
Seismic design.
Exception: Special reinforced masonry shear walls, where
the masonry resists the calculated shear without shear
reinforcement, need not comply with Section 1.14.2.2.5 (a) of
ACI 530/ASCE 5/TMS 402.
|